The X62T-NMT Tank Thermometer Interface is a special version of the X62T-HART. The main difference is that it emulates an Endress+Hauser Prothermo NMT539 so it can operate with an Endress+Hauser level gauge like the Micropilot NMR81 gauge.
Connects to ENRAF probes like:
• MTT/VITO with 16 or 9 spots (864, 764 and 767)
• MRT and MPT (863 and 361).
This way you can replace your Enraf level gauge and reuse the existing probe with minimal effort.
Configuration can be done using the local display of the level gauge and using the E+H device parameterization tools DeviceCare & FieldCare.
The X62T-NMT Tank Thermometer Interface is a special version of the X62T-HART. The main difference is that it emulates an Endress+Hauser Prothermo NMT539 so it can operate with an Endress+Hauser level gauge like the Micropilot NMR81 gauge. This way you can replace your Enraf level gauge and reuse the existing probe with minimal effort.
The X62T-NMT has it's combined force/sense inputs re-configured to measure:
• Enraf® MTT/VITO probes with 9 or 16 spots
• Enraf® MRT with or without Spot
• Enraf® 361 MPT
• Other probes having RTD elements in 3-wire Individual Sense or 4-Wire configurations
Commision using the level gauges local display or E+H device parametrization tools like DeviceCare and FieldCare
You won't have to worry about future compatibility to your level gauge or host since the X62T-NMT can be upgraded to X62T-HART to support the open HART® protocol